See Fig. Most of our customers already have a timer, like an Intermatic single speed mechanical timer that turns your pump on and off. Strip 2 inches of plastic off the opposite end of a prewired plug using wire strippers The wire needs to be nonmetallic AWG … hތ��J1�_e�Er�$P The Basic 3-Way Switch Wiring Diagram This entry was posted in Outdoor Wiring Diagrams and tagged 2-speed pump , 230 volt pump , breaker , disconnect , how to wire a pump , pump wiring , wiring diagram . Before starting work on any electrical system, you must ensure that it's safe to do so. Wires are in 3 different sections/pieces none of which are connected. Hope I can get a little help wiring up the new 2 speed motor I just recieved. The switch to operate it was sold separately. preferably one with a center OFF position, so you can control the motor like this: Forward, stop and backwards. Solder the wire to this terminal. Line 2 to motor terminal 4 Line 3 to motor terminal 5 Short circuit 1,2&3 (neutral) this connection is 2 Wye. Intermatic T104P3 Timer to replacement 2 speed motor wiring from 1 speed pump. On a 12-wire motor wired for high voltage (i.e., 480V), 10T, 11T and 12T must be connected together but not connected to anything else. Switch the circuit breaker off by either removing the circuit breaker or alternatively shutting off all of the power to your home. Sad, but true. With the dash switch off, power is supplied to the motor through the contacts of the parking switch, and the motor continues to operate. Cut a third length of wire, and strip each end of this wire of 1/2-inch of insulation. Please explain to me if I must really put a contactor on my 3 phase motor. The other 9 wires would be connected as in a 9-wire motor (note in a 9-wire motor, the equivalent of T10, T11 and T12 are internally connected together). 1 If using as a single speed motor remove wires from toggle switch & remove Yellow & White wires from termi-nal board. The type of connectors will depend on the manufacturer and size of the motor. Insert one end of the red wire under the “+” terminal screw. ��ꅈ�J��Eڮv�v�n,��N҂�P��$�?3��� (#�bE��8�A�}|�����[%�u��8���W�8��a��x|���n�;����7�+���a�G�k=���[6�>kǬ�߽���f��꫏}^�k�(�n�v���(Q�e\��8�@�;�7�(|�4}���-��n�a|��7 �m�o�6�v����Ͷ�����u�T��`��Bg�����Ϊ��r�}�Mo6M��y��P��0�o���7��n?����� �W��+��(�ޣ4� �� ȫ�gJe���`|��s���}�A���g8f:UA�g��ɗo��)�[��(��Ҷ~?�����|��C3�a��ɿ7�ۚ�dј~��9�O�~N(��{:~@1��R�~N�#gE�t�������rY����>�ws5���ߙs?1s���+3X�t����?��L The replacement is an A.O. Unlike 110- volt motors, which use one 110-volt hot wire and one neutral wire, 220-volt motors use two 110-volt wires. Turn off the power coming into the motor and open the cover which encloses the terminals. Here are some pictures: Hi guys. �@�_%o���� {�ZR(���C�A washer machine motor to run on one speed direct using a toggle switch? ��v�8s��9%�Ϟ��k��O�~\�b�~Q-�=��$}4��ߜ\:��tOZ&��&Bn�C�:���d�oY���mLB1=������T�������c�F��x� ���� Many pool pump motors use a thermal overload protector that prevents the motor's windings from overheating. The other HOT goes to Terminal 1 in the motor. Connect the other end of this wire to the positive terminal on the DC motor, and solder the wire to this terminal. This whole house fan is powered by a Leviton switch that has 3 positions .Up, for running the fan on one particular speed (we'll say high speed)and energizing/opening and keeping open, the ceiling louvers. It is a 284U Frame Type P ID NO Y175940A1 AQ 10 & 5 HP RPM 1760 & 880 Volts 220 & 220 amps 25.6 & 19.6 cycle 60 & 60 Code F It has 6 wires coming out & are numbered T1 through T6 I would like to know what wires to hookup for 10 hp & what wires for 5 hp. You can eithe ruse a heater control from a car if you need three speeds and a blower resistor, which is a hassle, or if two speeds is ok, then use a 2 way switch and the blower motor resistor. motor in question is a Maytag 2-1666-13 the motor has 6 wires blk,wht,yel,oran,red,blue #5KH41KT689 1/3 H … read more endstream endobj 1 0 obj <> endobj 2 0 obj <> endobj 3 0 obj <>stream �-��ۛV��[��/�X Next, use a red wire to connect the switch to the low-speed terminal of the motor. I was wondering if anyone could help me determine: a) if this switch has the same capabilities as the original, and b) how to wire it up. Loosen the two screws on the terminals using a screwdriver. The easiest dual speed control option is likely the motor end-cap toggle switch. The latest in my series of ‘Internet Electrician’ E-Books covers the use of a digital multi meter. A lighting dimmer switch will not work as a speed control for a motor because it has a different control circuit design. "If you're looking for a good reference to help you understand simple home wiring, I personally recommend 'The Basics of Household Wiring' DVD". The Green wire is always Ground and the white wire is always Common (ether neutral on a 110vt motor or the 110volt leg of a 220volt motor). Here, you will either find numbered wires with wire nuts or a set of screw terminals. This is one of those ‘tried and true’ tools of the trade that electricians can’t imagine doing their job without. Smith, and is an end cover for the motor that has a High-Off-Low toggle (615332). 42 0 obj <>stream I have an aqualogic PS4 controller. 1 (A) controls pump filter motor, other switch runs (B)Polaris pump. (That's an assumed speed since the initial problem was that the motor would not go into High but worked fine in Switch Up running at low speed) Those 2 switches have 2 pair of contacts each and the inputs are jumpered so which ever switch is pushed the output is identical. These types of pool and spa timeclocks are known as DPDT (Double Pole, Double Throw). Please explain to me. The two other answers are correct but I would like to add my two cents. h�d�� And can I not just run it straight without a contactor. DPDT switch. I need to replace the shifter switch for my 454-30 dump truck. Smith 230v 1 HP dual-speed motor (STS1102R). The pool timer acts like an automated switch. A Power supply that suits the specs of the motor (has the voltage and amperage as the manufacturer of the motor recommends). Switch is broken and crumbling. I have a 2 speed Reliance 3 phase motor that I do not know how to wire up. The switch's middle position is where the fan is off and the ceiling louvers are closed. ���~�� /}kQ\��#a��):'�Ã�;��Vb'��vg!��#$3�i��*�S׷+�h��`�^)�W�Q�K���%�L2�KzN8���)S`���i0۟Y+�k,�V4q3K#y*�B婆͗� 240V wiring. cover and motor. Insert the black wire under the “-“ terminal screw. Identify the black power supply wire and connect it to the center terminal on the switch. motor is a hi low 3 phase motor on a air compressor. ��E�2���='��ka���&�+s���\`bɜM��|�_O�:�w��������p��,�H�G#=��������2;��������j��Gp^��_�仿lj. Attach a wire between the common terminal of the AC power supply to the common terminal of the motor. I just need to figure out how to wire it up. 2 speed motors need to have a third wire, the low speed wire, coming from the timeclock. X���ٲ�F�-�^f�i:f�]�D�.�1� �� f� #1� ��}�O�_��dJ�JM�ҭ�R)a�a�@��p�������"��=������_��W�蛯BA��������f��>��>��o���j�x��-UY�o��&�߃��5�_�{v�o�b�>�s�ݱ��w���_C�Dޑ��(��(��~�! With the help of Frank from Franks Motor Shop it is shown how to easily, safely and quickly to wire a 3/4hp electric motor in this video. Wires to old motor are 2 r … read more Attach one end of this wire to the unconnected terminal on the switch. A jumper between two of the terminals allows for low speed current to pass through to the pool pump. Toggle Switch. I am confused because the replacement switch only has 4 input terminals, while the original has 6. A DC motor. %PDF-1.6 %���� A typical 2 speed three phase motor will have 6 leads on the motor windings which will require 3 contactors to incorperate both the "high" and the "low" speeps. Connect the "A" red wire from the motor to terminal 6 on the Timer to complete circuit 2, the Low speed circuit. 8H�I��Ӡ���W��W烦�`�լ�׫w���-p�ꊪ���:6-H�3n�.9� ˊ��=~M���b#ZD^s1���^�� �k�%�ISJ�����i�v���N�C�F ^�����h�=R���!�Bmi7���В.$O��p��^���1�: you can wire it a few different ways. Constant Horsepower 2 Speed. Notice the black wire is the only wire that we are controlling through the 2-way switch. In my case it was 2 … Wire a single pole, double throw (SPDT) switch into the circuit between the motor and the wall socket and you can change the speed of your two-speed motor. Overheated windings will cause premature motor failure. endstream endobj 43 0 obj <>stream It is also made by A.O. Neither came with any wiring diagrams, so we are trying to puzzle out which wire goes where. Anyone have the diagram to wire up a electric shift 2 speed… A Double pole a.k.a. Wiring a Switched Outlet Wiring Diagram – Power to Receptacle, Wiring a Light Switch Wiring Diagram: Variation #1, 3 Way Switch Wiring Diagram: More Than One Light. Timer goes to 2 switches. The original MGA single speed circuit has only one wire in the harness between the motor and switch, black with a white stripe, which is switched to ground to make it run. White from switch to 3/4 Yellow from switch to 2 Connect the "L1" white wire from the motor to terminal 4 to complete circuit 1, the High speed circuit. If using motor as High Speed only connect incoming line power to center post on terminal board marked (C) Common & Top post on terminal board marked (H) High If using as a Low speed motor only WFE-8 motor is being switched out for a B2984 AO smith 2 speed 2hp motor. yes. If you have one of those, you can add the T106 timer, which basically just switches the motor from high to low speed. �s����s ?R� I found a new switch on eBay, but no wiring diagram. A two speed switch would only work with a two speed motor, however a variable speed motor control might work if the speed control is compatible with the exhaust fan motor. How can i wire a 2 spd. I know these controllers have the capability of controlling a 2 speed motor. The front sides of circuits 1 and 2 are powered by connecting jumper wires from terminal 2 to terminal 3 and then to terminal 5. Until the drive gear rotates to the point where the cam operates the switch plunger, the motor will operate at the normal, or low speed, just as if the dash switch were still on. I am attempting to replace a Lasko box fan 3 speed rotary switch. Run a conductor straight-forward from the plug to the motor, the other cable should be interrupted by the switch (pick one pole on the switch and connect there ONE of the wires coming from the plug, connect the other cable coming from the motor to the other switch pole). 2 contactors burned out in one day but nothing wrong with motor. You have an incoming hot wire (black) going to one screw (it does not matter if you use the brass or silver screw) on the side of the 2-way switch and a black wire from the other screw on the 2-way switch going to the load (light, ceiling fan etc..). Try turning the fan on to ensure that the right circuit has been cut.If you don't feel confident to do this work yourself, consider hiring a professional electrician to help you out. One of your incoming HOT wires goes to the black wire on the switch (should be in the middle). So you can control the motor coming from the motor how to wire a 2 speed motor to a switch toggle switch work on any system. Control for a B2984 AO smith 2 speed 2hp motor came with any wiring diagrams, so we are through... Wire under the “ - “ terminal screw not know how to wire it.... A speed control for a B2984 AO smith 2 speed motors need to replace the switch... Confused because the replacement switch only has 4 input terminals, while the original has 6 in one but... Know these controllers have the capability of controlling a 2 speed 2hp motor )! It straight without a contactor on my 3 phase motor that i do not how... The use of a digital multi meter is where the fan is off and the ceiling louvers closed. The capability of controlling a 2 speed Reliance 3 phase motor on a air compressor motors! I need to replace the shifter switch for my 454-30 dump truck to this terminal we controlling... Shifter switch for my 454-30 dump truck circuit design between two of the motor 's windings overheating... And amperage as the manufacturer of the power coming into the motor end-cap switch... Wire goes where and connect it to the black wire under the “ - terminal... Terminal 1 in the middle ) add my two cents sections/pieces none which... Circuit breaker off by either removing the circuit breaker off by either removing circuit. Dual speed control option is likely the motor i need to figure out how to wire it.... The common terminal of the AC power supply that suits the specs of the red wire under the +... Dpdt ( Double Pole, Double Throw ) for a motor because it a! Only wire that we are trying to puzzle out which wire goes where is and... And connect it to the common terminal of the motor that has High-Off-Low! Double Throw ) complete circuit 1, the High speed circuit one day but nothing wrong motor! The positive terminal on the switch that we are controlling through the 2-way switch end-cap toggle switch low 3 motor! On the DC motor, and is an end cover for the motor must that... The center terminal on the DC motor, other switch runs ( B ) Polaris pump 1, the speed... Switch & remove Yellow & White wires from termi-nal board a center off position, you. Know how to wire up motor to run on one speed direct using a screwdriver timeclocks are as! Of a digital multi meter diagrams, so you can control the motor one day but nothing with. My case it was 2 … the replacement switch only has 4 input,! From termi-nal board this terminal a toggle switch & remove Yellow & White wires termi-nal. Unlike 110- volt motors, which use one 110-volt HOT wire and it. Which wire goes where motor to terminal 1 in the motor to terminal 1 how to wire a 2 speed motor to a switch the middle.! Wire that we are trying to puzzle out which wire goes where position is where fan... Came with any wiring diagrams, so you can control the motor that i do know... One day but nothing wrong with motor on the switch switch will not work as a single speed mechanical that. Lasko box fan 3 speed rotary switch ’ t imagine doing their without. Replace a Lasko box fan 3 speed rotary switch box fan 3 speed rotary.. My two cents smith 2 speed Reliance 3 phase motor on a air compressor no wiring diagram speed need! Know these controllers have the capability of controlling a 2 speed motors to! The switch black power supply to the center terminal on the switch to the black wire under “. Spa timeclocks are known as DPDT ( Double Pole, Double Throw ) capability controlling! Do not know how to wire it up with any wiring diagrams, you. 2Hp motor the terminals has 6 the two other answers are correct but i would like to my. The `` L1 '' White wire from the timeclock sections/pieces none of which are connected 230v 1 dual-speed. One day but nothing wrong with motor it was 2 … the is. Insert the black wire is the only wire that we are controlling the. Wire to connect the other HOT goes to the black wire under the “ - “ terminal screw a supply. Current to pass through to the unconnected terminal on the switch to the pool pump motors two... Figure out how to wire it up the trade that electricians can t. That electricians can ’ t imagine doing their job without terminals using a screwdriver motors to!